Educated Design & Development has been named an company.
Top

IP Code Testing

Available with IEC/ISO 17025 Certificate of Calibration
Ingress Protection Test Equipment is used to determine the degree of protection provided by a product enclosure. The level of protection provided by an enclosure is represented by an "IP" code (i.e. IP43). The first digit indicates protection against ingress of solid foreign objects. Many of these tests require accessibility probes. The equipment for these tests is provided below. All equipment fully complies with IEC 60529 (IP Code standard) and all other international standards with similar tests.

IP Code PROBES All Products (IP Code Testing)
1X Protection against objects >50mm X1 Protection against vertically dripping water
2X Protection against objects >12.5mm X2 Dripping water ± 15° from vertical
3X Protection against objects >2.5mm X3 Protection against spraying water
4X Protection against objects >1.0mm X4 Protection against splashing water
5X Dust Protected (limited ingress) X5 Protection against low pressure jetting water
6X Dust Tight Protection X6 Protection against high pressure jetting water
UL UL Standard Test Equipment X6K Extremely high pressure jetting water

IP6X

DTC Dust Chambers
above: Dust Ingress Testing Chamber
Product Details

For checking the protection against solid foreign objects to verify the degrees of protection IP5X "Dust-protected" and IP6X "Dust-tight." Manufactured from rectangular steel tubes and sheet steel, with 4 lockable dolly's (wheels), control cabinet with control and monitoring elements located on the right-hand side, voltages and/or frequencies according to customer needs.



Model Internal Depth External Depth External Width External Height Dust Pumps, Vibrators Slides for Specimens Cabinet Walls
DTC-100 800 mm 1000 mm 1320 mm 1910 mm 1 1 Painted Steel
DTC-200 1600 mm 1800 mm 1320 mm 1910 mm 2 2 Painted Steel
DTC-300 2400 mm 2600 mm 1320 mm 1910 mm 3 2 Painted Steel
Product Details

  • TX0005 75 micron Talc (Agalite)
  • 10 Kg Bucket / 1.55 Kg Container
  • Standard specifies that talcum must be replaced every 20 tests.
  • Standard specifies that dust volume must be 2 Kg / m3

Model Container Weight
DTC-810 10 KG
DTC-825 1.55 KG
[HOME] [ABOUT] [CALIBRATION] [STORE FRONT] [CONTACT]

Educated Design & Development, Inc.

901 SHELDON DRIVE

Cary, NC 27513 USA

Tel: 800-806-6236

Tel: (Int.) 001-919-469-9434

Fax: 919-469-5743

Educated Design & Development, Inc. © 2011 All Rights Reserved.
ED&D products are RoHS, REACH, and Conflict-Minerals Free

[Hipot Testers] [Ground Continuity Testing] [Leakage Current Testing] [Accessibility Probes] [Impact Testing]
[Temperature Measurement] [Voltage Current & Power Measurement] [Force & Torque Measurement] [Power Control]
[Loading Devices] [Flame & Other Plastics Testing] [Ingress Protection Testing] [Plug, Socket & Cord Testing]
[Breaking Capacity Testing] [Abnormal Testing] [Environmental Testing] [Creepage & Clearance Testing] [Other Safety Products]
[Safety Labels] [Toy Testing]